1.1 This specification covers cold-rolled carbon steel coils or strip used in the fully processed condition in magnetic lamination applications.
1.2 This steel is produced to specified maximum core-loss values and is intended primarily for commercial power frequency (50- and 60-Hz) applications in magnetic devices. Desirable core-loss and permeability characteristics are developed during mill processing, so further heat treatment by the purchaser is not necessary for most uses.
1.3 Fully processed magnetic lamination steels are flat-rolled low carbon iron alloys having 1 % maximum silicon and 0.4 % maximum aluminum.
1.4 The values stated in customary (cgs-emu and inch-pound) units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units, which are provided for information only and are not considered standard.
| SDO | ASTM: ASTM International |
| Document Number | A840 |
| Publication Date | Oct. 10, 2000 |
| Language | en - English |
| Page Count | 4 |
| Revision Level | 00 |
| Supercedes | |
| Committee | A06.02 |