1.1 This specification covers the requirements to which the specified grades of soft magnetic manganese zinc (MnZn) ferrite materials shall conform. Cores made from these materials are used primarily in transformers and inductors.

1.2 Frequency—MnZn ferrite cores are primarily used for frequencies in the range of 10 kHz to 1 MHz. Many inductors have a DC component as well.

1.3 Magnetic Flux Density—Applications consist of two main categories, high and low magnetic flux density.

1.3.1 High Magnetic Flux Density—Transformers used for power conversion. Inductors or chokes used in high current applications.

1.3.2 Low Magnetic Flux Density—Transformers, inductors, chokes used for signal conditioning.

1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to customary (cgs-emu and inch-pound) units, which are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


This specification deals with soft magnetic manganese zinc ferrite core materials for high frequency power transformer and filter inductor applications. Standard types of both power transformer and filter inductor material are defined. For power transformer use, there are five types defined by their maximum core loss density and minimum saturation flux density. For filter inductor materials, three types are defined based on their inductance permeability. Apart from magnetic property requirements, dimensional tolerances and workmanship requirements are defined in this specification.


SDO ASTM: ASTM International
Document Number A1009
Publication Date Oct. 1, 2018
Language en - English
Page Count 4
Revision Level 18
Supercedes
Committee A06.02
Publish Date Document Id Type View
Nov. 1, 2024 A1009-18R24E01 Revision
Oct. 1, 2018 A1009-18 Revision
Nov. 1, 2005 A1009-05 Revision
May 10, 2000 A1009-00 Revision
Nov. 1, 2010 A1009-05R10 Reaffirmation